XES 120 mobilt batteri
                                    Last ned                                
                                
                        Nominal rating @ 25 °C
                                            
                    72 kW (90 kVA)
                
                        Frequency
                                            
                    50 Hz
                
                        Voltage
                                            
                    400/230 VAC
                
                        Passthrough current (genset only)
                                            
                    200 A
                
                        Max. combined current (genset+XES)
                                            
                    250 A
                
                        Max. load before genset start (fast)
                                            
                    Configurable 57.6 kW - 64.8 kW / delay 0- 30s
                
                        Max. load before genset start (slow)
                                            
                    Configurable 54.0 kW - 61.2 kW / delay 60-600s
                
                        Overload
                                            
                    1.5 x rated for 30s
                
                        Short-circuit current
                                            
                    2 x rated current
                
                        Inverter derate @ 30°C
                                            
                    96 %
                
                        Inverter derate @ 40°C
                                            
                    90 %
                
                        Inverter derate @ 50°C
                                            
                    82 %
                
                        Nominal capacity @ 25 °C
                                            
                    127.9 kWh
                
                        Typcial charge time @ 25°C
                                            
                    3 hr
                
                        Battery chemistry
                                            
                    Lithium iron phosphate (LFP)
                
                        Cycle life (80% DoD)
                                            
                    6000 cycles
                
                        Maintenance charge interval
                                            
                    <3 weeks
                
                        Cooling
                                            
                    Variable speed force air coolingOpen charge 
                
                        Ingress rating
                                            
                    point IP55 / NEMA 3
                
                        Operating temperature range (charge)
                                            
                    0 to +50 °C
                
                        Operating temperature range (discharge)
                                            
                    -10 to +50 °C
                
                        Dimensions [LxWxH]
                                            
                    2250 x 1398 x 2126 mm
                
                        Weight
                                            
                    2800 kg
                Details are given for guidance only. Exact equipment may vary according to geographical location and availability.
 